Guaranteed Success in DCS-IE DES-4122 Exam Dumps EMC DES-4122 Daily Practice Exam New 2022 Updated 60 Questions NEW QUESTION 20 Starting from which Dell EMC PowerEdge server hardware generation is the Micro SD card in the IDSDM/vFlash module supported? A. 12G B. 14G C. 11G D. 13G Answer: B NEW QUESTION 21 A Dell EMC PowerEdge R740 server requires a vFlash SD card urgently. Additional vFlash Cards and [...]

Guaranteed Success in DCS-IE DES-4122 Exam Dumps [Q20-Q43]

Share

Guaranteed Success in DCS-IE DES-4122 Exam Dumps

EMC DES-4122 Daily Practice Exam New 2022 Updated 60 Questions

NEW QUESTION 20
Starting from which Dell EMC PowerEdge server hardware generation is the Micro SD card in the IDSDM/vFlash module supported?

  • A. 12G
  • B. 14G
  • C. 11G
  • D. 13G

Answer: B

 

NEW QUESTION 21
A Dell EMC PowerEdge R740 server requires a vFlash SD card urgently. Additional vFlash Cards and components from other servers are available.
What is the recommended solution?

  • A. Reuse an existing vFlash SD card from either a 13G or 14G server
  • B. Use a configuration option to convert an NVMe drive to a virtual vFlash
  • C. Reuse an existing vFlash SD card from a 14G server
  • D. Use a configuration option to convert BOSS to a virtual vFlash

Answer: C

 

NEW QUESTION 22
What happened on April 30, 2019?


Note: It is necessary to dose (x) the simulator window before you can select a response to this question.

  • A. Option C
  • B. Option D
  • C. Option B
  • D. Option A

Answer: A

 

NEW QUESTION 23
A technician wants to remotely log in to a server but finds that the IDRAC virtual Console feature Is not available. Use the simulator to explore the system. What Is the cause of this Issue?


Note: It is necessary to dose (x) the simulator window before you can select a response to this question.

  • A. Operating system not installed on remote server
  • B. The Virtual Console is disabled
  • C. The server has been powered down
  • D. There are more than the maximum number of active sessions

Answer: C

 

NEW QUESTION 24
A technician is sent on-site to troubleshoot a server that produced an error message during the most recent POST, but then completed the POST and booted to the operating system. The user cannot remember the specific error and no entry was made in the error log relating to this error.
How can the technician find out what the error message was?

  • A. Access the Lifecycle Controller and view the last boot cycle video capture entry
  • B. Reload the BIOS firmware
  • C. Export the Server profile and analyze for any POST errors
  • D. Access the iDRAC and view the last boot cycle video capture entry

Answer: A

 

NEW QUESTION 25
You are Investigating a disk error on a Dell EMC PowerEdge server and discover a Hot Spare has not been assigned to the Virtual Disk Group. Use the simulator to assign the Global Hot Spare. When you have finished using the simulator, dick Next.

Answer:

Explanation:
Send us your suggestion for this simulation task.

 

NEW QUESTION 26
You are creating a new RAID 5 storage pool on a Dell EMC PowerEdge server based on 30 x 1TB drives Which PERC model best supports this configuration?

  • A. H740T
  • B. S140
  • C. H330
  • D. H740P

Answer: B

 

NEW QUESTION 27
For security reasons, the Dell EMC PowerEdge server power button must be disabled. Use the System Setup Utility in the simulator to disable the power button. When you have finished using the simulator, click Next.

Answer:

Explanation:
Send us your suggestion for this simulation task.

 

NEW QUESTION 28
A technician working with a Dell EMC PowerEdge 1 take corrective action?

  • A. Check the LCC Log
    Check PSU LED
    Reseat the CPU
  • B. Check the System Event Log
    Check PSU LED
    Reseat the PSU
  • C. Check the System Event Log
    Check PSU LED
    Do a virtual reseat of the iDRAC
  • D. Check the LCC Log
    Check PSU LED
    Reseat the PSU

Answer: C

 

NEW QUESTION 29
How can a technician know whether IDRAC9 System Lockdown mode is enabled?

  • A. Lockdown activation message in yellow box in the iDRAC web GUI Access to LCC is disabled when the server boots
  • B. Lockdown activation message in red box in the iDRAC web GUI Access to LCC requires a password when the server boots
  • C. Lockdown activation message in red box in the iDRAC web GUI Access to LCC is disabled when the server boots
  • D. Lockdown activation message in yellow box in the iDRAC web GUI Access to LCC requires a password when the server boots

Answer: C

 

NEW QUESTION 30
A technician needs to change the iDRAC password on a Dell EMC PowerEdge 14G server in a lights-out datacenter. The be rebooted because it is in production. The iDRAC is configured with the default credentials How could the technician change the iDRAC password?

  • A. OpenManage Server Administrator
  • B. iDRAC Web GUI
  • C. Virtual Console; press F2 after rebooting system
  • D. SupportAssist Enterprise

Answer: D

 

NEW QUESTION 31
A Dell EMC PowerEdge server has been updated with an LCC and iDRAC DUP to the latest firmware when performing a firmware rollback?

  • A. The LCC can be rolled back; the iDRAC cannot be rolled back
  • B. The iDRAC can be rolled back; the LCC cannot be rolled back
  • C. Both the iDRAC and the LCC can be rolled back
  • D. The iDRAC cannot be rolled back and the LCC cannot be rolled back

Answer: A

 

NEW QUESTION 32
A Dell EMC PowerEdge server logs the following CPU Machine Check error CPU1 IERR What action might solve the problem?

  • A. Update the Intel driver
  • B. Remove flea power
  • C. Swap the PERC controller
  • D. Reseat the IDSDM

Answer: A

 

NEW QUESTION 33
Which card connects to the PCI bus, is physically smaller than a on the system board of a Dell EMC PowerEdge 14G server?

  • A. NDC
  • B. OCP
  • C. FPGA
  • D. PCIe

Answer: D

 

NEW QUESTION 34
Which processor configuration is used by the Dell EMC PowerEdge R740 server?

  • A. 2 socket AMD
  • B. 4 socket Intel
  • C. 4 socket AMD
  • D. 2 socket Intel

Answer: D

 

NEW QUESTION 35
Match each RAID level to its characteristic.

Answer:

Explanation:

 

NEW QUESTION 36
What is a key feature introduced in OpenManage Mobile v2.0?

  • A. Access servers remotely through OME
  • B. Access a Virtual Console (VNC over SSH) securely
  • C. Access SupportAssist reports
  • D. Access iDRAC remotely

Answer: C

 

NEW QUESTION 37
A technician needs to repurpose a Dell EMC PowerEdge server. The server has dual processors with 18 cores each The OS only "sees" 24 threads in total.
Which setting should the technician change in Processor Settings in the System BIOS?

  • A. Virtualization Technology
  • B. System Profile
  • C. Number of Cores per Processor
  • D. HyperThreading

Answer: B

 

NEW QUESTION 38
Dell EMC PowerEdge 14G servers support which technology?

  • A. Quicksync 1.0
  • B. Intel Boot Guard
  • C. AMD GuardMI
  • D. iDRAC8

Answer: C

 

NEW QUESTION 39
What is the drive characteristic of a BOSS M.2 drive in a Dell EMC PowerEdge server?

  • A. Quad-level cell
  • B. Read Intensive
  • C. Write Intensive
  • D. Single-level cell

Answer: D

 

NEW QUESTION 40
A technician installs eight servers into a fully operational rack with top of rack switch Each server has a quad
1Gb NIC and redundant power supplies The company uses iDRAC in shared LOM mode with LOM1 as the selected NIC What should the technician do to verify iDRAC connectivity on each server?

  • A. iDRAC dedicated NIC port is cabled and the link light is green
  • B. iDRAC Enterprise license is installed
  • C. Ethernet port LOM1 is cabled and the link light is green.
  • D. iDRAC Datacenter license is installed.

Answer: A

 

NEW QUESTION 41
Which rear disk drive option is available in a Dell EMC PowerEdge R740xd server?

  • A. 6x2 5" drives
  • B. 2x3.5" drives
  • C. 8x2 5" drives
  • D. 4x 3.5" drives

Answer: B

 

NEW QUESTION 42
A system engineer has a 14G Dell EMC Poweredge server with an amber light blinking. The engineer must pull a SupportAssist collection before calling Dell Support to evaluate what the potential problem. Use the simulator to collect and view the SupportAssist collection.